Electronic control fuel injection system (Common rail type) 1E-209 Characteristics of barometric pressure sensor Breaker box inspection procedure The output voltage of barometric pressure sensor changes according to the barometric pressure. The scan tool with CAN communication displays a fixed value when the value exceeds the threshold voltage. Therefore, judge as it is more than the threshold value if the value of 40 kPa (5.8 psi) or 120 kPa (17.4 psi) is not changed. When error occurs, error value (127 kPa {18.4 psi}) is displayed. The following illustration shows the correlation between physical value and voltage displayed in the scan tools with CAN communication.
Tech2 and scan tools with KW communication can display both physical value and voltage. Perform the inspection in the following procedure if there is such an instruction to use breaker box in the step. After inspection, return to the diagnostic step. (V) 2.279198 Name 1. Breaker box 2. DMM 1.009671 40(5.8) 120(17.4) kPa(psi) TSWG0205 Step Item to be checked Inspection method Measuring condition Terminal No. Normal value Abnormal value 6 Open circuit/ high resistance Resistance measurement • Disconnect the sensor connector.
• Key switch “OFF” 61 - Sensor connector power supply terminal 100 Ω or less 10 MΩ or more 7 Short circuit to ground circuit/ ground Resistance measurement • Disconnect the sensor connector. • Key switch “OFF” 71 - 60 71 - Ground 10 MΩ or more 100 Ω or less Open circuit/ high resistance Resistance measurement • Disconnect the sensor connector. • Key switch “OFF” 71 - Sensor connector signal terminal 100 Ω or less 10 MΩ or more