hitachi — DTC: P0193 (Flash code 245) Common rail pressure sensor fault (high voltage fault, open circuit)

1E-268 Electronic control fuel injection system (Common rail type) Step Action Value YES NO 5 1. Turn the key switch to “OFF”. 2. Disconnect the common rail pressure sensor connector. 3. Short the common rail pressure sensor connector power supply terminal and the signal terminal using jump cable. 4. Turn the key switch to “ON”. 5. Check the value for “Common rail pressure sensor” using scan tool. Is the “Common rail pressure sensor” less than the specified value? 4.8V Go to Step 9. Go to Step 6. 6 1. Check the signal circuit between ECM and common rail pressure sensor for short circuit to the power supply circuit or ignition power supply circuit using breaker box or DMM.

Refer to “Breaker box inspection procedure”. Note: If breaker box is not available, refer to “On- board check procedure for sensors”. Important: If the common rail pressure sensor circuit is shorted to the power supply circuit, the sensor may be broken. 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 13. Go to Step 7. 7 1. Check for followings in the signal circuit between ECM and common rail pressure sensor using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note: If breaker box is not available, refer to “On- board check procedure for sensors”. • Open circuit • High resistance 2.

If the trouble is detected, repair or replace as required. Is the trouble detected? — Go to Step 13. Go to Step 8.