Electronic control fuel injection system (Common rail type) 1E-271 Characteristics of common rail pressure sensor Breaker box inspection procedure Perform the inspection in the following procedure if there is such an instruction to use breaker box in the step. After inspection, return to the diagnostic step. 4.2 (V) 1 0 200(29008) MPa(psi) TSWG0201 Name 1. Breaker box 2. DMM Step Item to be checked Inspection method Measuring condition Terminal No. Normal value Abnormal value 6 Short circuit to power supply circuit Voltage measurement • Disconnect the sensor connector.
• Key switch “ON” 82 - Ground 90 - Ground 0V 18V or more 7 Open circuit/ high resistance Resistance measurement • Disconnect the sensor connector. • Key switch “OFF” 82 - Sensor connector signal terminal 90 - Sensor connector signal terminal 100 Ω or less 10 MΩ or more 8 Open circuit/ high resistance Resistance measurement • Disconnect the sensor connector. • Key switch “OFF” 101 - Sensor connector ground terminal 100 Ω or less 10 MΩ or more