hitachi — DTC: P0238 (Flash code 32) Boost pressure sensor fault (high voltage fault, short to power supply circuit, ground open circuit)

Electronic control fuel injection system (Common rail type) 1E-317 Characteristics of boost pressure sensor Breaker box inspection procedure The output voltage of boost pressure sensor changes according to the boost pressure. The scan tool with CAN communication displays a fixed value when the value exceeds the threshold voltage. Therefore, judge as it is more than the threshold value if the value of 40 MPa (5802 psi) or 350 MPa (50763 psi) is not changed. When error occurs, error value (508 MPa {73679 psi}) is displayed. The following illustration shows the correlation between physical value and voltage displayed in the scan tools with CAN communication.

Tech2 and scan tools with KW communication can display both physical value and voltage. Perform the inspection in the following procedure if there is such an instruction to use breaker box in the step. After inspection, return to the diagnostic step. 4.75026 (V) Name 1. Breaker box 2. DMM 0.100082 40(5802) 350(50763) MPa(psi) TSWG0063 Step Item to be checked Inspection method Measuring condition Terminal No. Normal value Abnormal value 6 Short circuit to power supply circuit Voltage measurement • Disconnect the sensor connector. • Key switch “ON” 91 - Ground 0V 18V or more 7 Open circuit/ high resistance Resistance measurement • Disconnect the sensor connector.

• Key switch “OFF” 109 - Sensor connector ground terminal 100 Ω or less 10 MΩ or more