Electronic control fuel injection system (Common rail type) 1E-347 Breaker box inspection procedure Perform the inspection in the following procedure if there is such an instruction to use breaker box in the step. After inspection, return to the diagnostic step. Name 1. Breaker box 2. DMM Step Item to be checked Inspection method Measuring condition Terminal No. Normal value Abnormal value 8 Open circuit/ high resistance Resistance measurement • Disconnect the relay. • Key switch “OFF” 10 - FL 12 connector terminal No. 1 10MΩ or less 10 MΩ or more Short circuit to ground Resistance measurement • Disconnect the relay.
• Key switch “OFF” 10 - Ground 10 MΩ or more 10MΩ or less 10 Short circuit to power supply circuit Voltage measurement • Disconnect the relay. • Key switch “ON” 10 - Ground 0V 18V or more