hitachi — DTC: P0615 (Flash code 19) Starter cut relay circuit fault

Electronic control fuel injection system (Common rail type) 1E-391 DTC: P0615 (Flash code 19) Starter cut relay circuit fault (*: Specifications (fuse current value etc.) vary depending on each machine. Refer to the machine manual.) (100A)* B Starter C Battery B Generator (15A)* (60A)* Glow relay Main relay Starter cut relay Starter cut relay (10A)* 1 H-22 0.5 B/W 1 H-1 10 E-57 Key switch E-57 14 Glow relay control Glow plug Engine control module (ECM) Starter cut relay signal TSWG0072 Description of circuit Main trouble symptom The starter cut switch is provided to prevent the starter from operating while the engine is running.

The starter cut relay is the normal-close relay, and is located between the main relay and the starter relay. When the key switch is turned to “ON”, the ECM sends the signal to the starter cut relay to turn the relay “OFF”. When starting the engine, once the key switch is turned to “START” position, the ECM stops the signal output to the starter cut relay, and this enables the relay to turn “ON”. After starting the engine, when the key switch returns to “ON” position, the ECM sends the signal to the starter cut relay again to turn the relay “OFF”. A monitor circuit is provided inside the ECM to monitor the relay operation.

The ECM sets the DTC when the output to the starter cut relay does not match with the starter cut relay operation. Operationality is not affected. Preconditions when DTC is set Key switch input power supply voltage is higher than 16 V but lower than 32 V. DTC set condition No starter cut relay monitor signal exists against starter cut relay drive signal. Action taken when DTC is set Trouble is displayed on the monitor of the machine or diagnosis lamp comes on. A B Br C (ON) (ST) OFF ON START A B ACC Br C (ON) (ST) OFF ON START B Br (ON) C (ST) OFF ON START B ACC Br (ON) C (ST) OFF ON START