hitachi — DTC: P1094 (Flash code 226) No pump pressure feed (1st stage)

1E-414 Electronic control fuel injection system (Common rail type) Poor connection of terminal from connector Unmatched terminals are fitted. Damage of connector lock Poor contact between terminal and wire Damaged harness Visually check the harness for damage. Check the relevant items on the scan tool data display while moving the connector and the harness which are related to the sensor. The variation of the display indicates the faulty part. Test description Numbers below indicate step numbers in the chart. 4. If no DTC is detected, mixing of air in the fuel may be the cause of DTC detection. 7.

If the “Common rail pressure sensor” displays more than the specified value when the common rail pressure sensor connector is removed, the circuit beyond the sensor is normal including ECM. Step Action Value YES NO 1 Perform the OBD system check. Is the procedure completed? — Go to Step 2. Go to “OBD system check”. 2 1. Start the engine. 2. Check the DTC. Is DTC P0091, P1291, or P1093 not detected? — Go to DTC P0091, P1291, or P1093. Go to Step 3. 3 1. Perform the fuel system check. Check the fuel filter for clogging. If it is dirty, replace the main fuel filter and pre- fuel filter. 2. If the trouble is detected, repair as required. Is the procedure completed? — — Go to Step 4. 4 1.

Turn the key switch to “OFF” for more than 10 seconds. 2. Start the engine, and run with the “Preconditions when DTC is set”. 3. Check the DTC. Is DTC P1094 detected? — Go to Step 5. Go to “Diagnostic aid”. 5 Is the scan tool (KW communication) available? — Go to Step 6. Go to Step 19. 6 1. Clear the DTC. Refer to “How to clear diagnosis trouble code (DTC)” of “Procedure of trouble diagnosis” in this section for how to clear DTCs. 2. Start the engine. 3. Select the “Actuator test” from the menu. 4. Select the “Rail pressure control” in the “Common rail system”. 5. Press the “Up” soft key to check the value of “Common rail pressure”. Is “Common rail pressure” within the specified value?

±5 MPa (±725 psi) Go to Step 13. Go to Step 7.