hitachi — DTC: P1112 (Flash code 295) Boost temperature sensor fault (low voltage fault, ground short)

Electronic control fuel injection system (Common rail type) 1E-435 Breaker box inspection procedure Perform the inspection in the following procedure if there is such an instruction to use breaker box in the step. After inspection, return to the diagnostic step. Name 1. Breaker box 2. DMM Step Item to be checked Inspection method Measuring condition Terminal No. Normal value Abnormal value 6 Open circuit/ high resistance Resistance measurement • Disconnect the sensor connector. • Key switch “OFF” 74 - Sensor connector signal terminal 100 Ω or less 10 MΩ or more 7 Short circuit to ground circuit/ ground Resistance measurement • Disconnect the sensor connector.

• Key switch “OFF” 74 - 109 74 - GND 10 MΩ or more 100 Ω or less Open circuit/ high resistance Resistance measurement • Disconnect the sensor connector. • Key switch “OFF” 74 - Sensor connector signal terminal 100 Ω or less 10 MΩ or more