1E-434 Electronic control fuel injection system (Common rail type) Characteristics of boost temperature sensor The output voltage of boost temperature sensor changes according to the boost temperature. The scan tool with CAN communication displays a fixed value when the value exceeds the threshold voltage. Therefore, judge as it is more than the threshold value if the value of 40 ° C ( 40 ° F) or 120 ° C (248 ° F) is not changed. When error occurs, error value (214 ° C {419 ° F}) is displayed. The following illustration shows the correlation between physical value and voltage displayed in the scan tools with CAN communication.
Tech2 and scan tools with KW communication can display both physical value and voltage. (V) 4.9824 1.1719 -40 (-40) 120 (248) TSWG0204 F 1000 100 10 Resistance 1 0.1 0.01 -40 (-40) -30 (-22) -20 (-4) -10 (14) 0 (32) 10 (50) 20 (68) 30 (86) 40 (104) 50 (122) 60 (140) 70 (158) 80 (176) 90 (194) 100 (212) 110 (230) 120 (248) 130 (266) 140 (284) 150 (302) Temperature TSWG0060