hitachi — DTC: P1225 (Flash code 31) Idle UP/DOWN switch fault

Electronic control fuel injection system (Common rail type) 1E-453 About idling control switch Note: Refer to the machine’s manual for installing position of the idling control switch. Breaker box inspection procedure Perform the inspection in the following procedure if there is such an instruction to use breaker box in the step. After inspection, return to the diagnostic step. Name 1. Breaker box 2. DMM Step Action Value YES NO 11 Check if other DTC is detected. Is other DTC detected? — Go to each DTC diagnosis. Verify repair. Step Item to be checked Inspection method Measuring condition Terminal No.

Normal value Abnormal value 4 Short circuit to power supply circuit Voltage measurement • Disconnect the switch connector. • Key switch “ON” 30 - Ground 0V 18V or more 5 Short circuit to power supply circuit Voltage measurement • Disconnect the switch connector. • Key switch “ON” 31 - Ground 0V 18V or more