hitachi — DTC: P1225 (Flash code 31) Idle UP/DOWN switch fault

1E-452 Electronic control fuel injection system (Common rail type) Step Action Value YES NO 5 1. Check the idle down-side circuit between idling control switch and ECM for short circuit to the power supply circuit or ignition power supply circuit using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note: If breaker box is not available, refer to “On- board check procedure for sensors”. 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 10. Go to Step 7. 6 Replace the idling control switch. Is the procedure completed? — Go to Step 10. — 7 Is EMPS available? — Go to Step 8. Go to Step 9. 8 1. Check the version of ECM software. 2.

Rewrite the software if version upgraded is necessary. Refer to “How to use flash tool” in this section for check and rewriting of ECM. Note: EGR valve position learning is required after replacing or rewriting the ECM. Refer to “Engine Control System, Engine control module (ECM), Installation of ECM” in this section for learning of EGR. Is the procedure completed? — Go to Step 10. Go to Step 9. 9 Replace the ECM. Note: EGR valve position learning is required after replacing or rewriting the ECM. Refer to “Engine Control System, Engine control module (ECM), Installation of ECM” in this section for learning of EGR. Is the procedure completed? — Go to Step 10.

— 10 Check if DTC is not detected again. 1. Connect all the harnesses. 2. Clear the DTC. Refer to “How to clear diagnosis trouble code (DTC)” of “Procedure of trouble diagnosis” in this section for how to clear DTCs. 3. Turn the key switch to “OFF” for more than 15 seconds, and then start the engine. 4. Check the DTC. Is the procedure completed? — Go to Step 11. —