1E-484 Electronic control fuel injection system (Common rail type) About AP sensor Breaker box inspection procedure Refer to the machine’s manual for installing position of the AP sensor. Perform the inspection in the following procedure if there is such an instruction to use breaker box in the step. After inspection, return to the diagnostic step. Characteristics of AP sensor (V) 4 1 0 99.8 (%) TSWG0200 Name 1. Breaker box 2. DMM Step Action Value YES NO 16 1. Turn the key switch to “OFF”. 2. Disconnect the AP sensor connector. 3. Short between the sensor power supply terminal of the AP sensor connector and the sensor 1 signal terminal using jump cable. 4. Turn the key switch to “ON”. 5.
Check for “Accelerator sensor 1” on the data display. Is the “Accelerator sensor 1” more than the specified value? 4.8V Go to Step 8. Go to Step 6. Step Item to be checked Inspection method Measuring condition Terminal No. Normal value Abnormal value 6 Open circuit/ high resistance Resistance measurement • Disconnect the sensor connector. • Key switch “OFF” 42 - Sensor connector sensor 1 power supply terminal 100 Ω or less 10 MΩ or more 7 Short circuit to ground circuit/ ground Resistance measurement • Disconnect the sensor connector. • Key switch “OFF” 63 - 41 63 - Ground 10 MΩ or more 100 Ω or less Open circuit/ high resistance Resistance measurement • Disconnect the sensor connector.
• Key switch “OFF” 63 - Sensor connector sensor 1 signal terminal 100 Ω or less 10 MΩ or more