Electronic control fuel injection system (Common rail type) 1E-45 5. Send the instruction to glow plug relay and check whether the lamp on the machine operates. 5. Send the instruction to EGR valve and check the data list. % % % TSWG0134 TSWG0135 6. If the lamp operates properly, it is judged as normal. 6. If variation of data list is proper value, EGR valve is judged as normal. EGR regulating valve test View captured data. This test is performed to check the operation of EGR valve. The Tech2 must be used in this test. Test procedure 1. Connect the Tech2 to the machine DLC. 2. Start the engine and run it at idle. 3. Select the Device Control. 4. Select the EGR Control.
The Snapshot data acquired through the application menu “F2: Snapshot” under the “Main Menu, F0: Diagnostics” can be replayed. Since the data is saved on the PCMCIA card, it can be viewed after disconnecting the Tech2 (DLC) from the machine. Two data items can be saved there. The internal clock of the Tech2 needs to be set precisely, since the data are identified with dates and times. Sample use of snapshot data replay 1. Turn on the power. TSWG0140 TSWG0110