1E-506 Electronic control fuel injection system (Common rail type) Recovery from failure Following inspections are necessary to detect these causes. Improper connection of harness connector and ECM connector Poor connection of terminal from connector Unmatched terminals are fitted. Damage of connector lock Poor contact between terminal and wire Damaged harness Visually check the harness for damage. Check the relevant items on the scan tool data display while moving the connector and the harness which are related to the sensor. The variation of the display indicates the faulty part.
Refer to “List of diagnostic trouble code” and “About recovery from failure” in this section for recovery from failure. The conditions to clear the MIL/DTC The present trouble turns to history trouble when the condition is out of the range from DTC set condition (recovery from failure). The diagnosis lamp will go off after the code turns to history trouble and the key switch is turned “OFF” then “ON” again. Using the scan tool, or memory clear switch and diagnostic switch operation enables to clear DTCs. Diagnostic aid Test description If the intermittent trouble is suspected, followings may be the cause.
Fault in switch body Improper adjustment of switch Improper connection of harness connector Defective harness routing Worn harness cladding Wire disconnection inside harness cladding Numbers below indicate step numbers in the chart. 4. If the main relay is stuck closed, it is possible to communicate with ECM using scan tool even with the key switch “OFF”. 5. If it is still possible to communicate with ECM using scan tool and the DTC is detected when the main relay is removed, the circuit beyond the relay or ECM is faulty. 8.
If the “Main relay voltage” displays more than the specified value when terminals between the main relay installing portion are shorted, the circuit beyond the relay is normal including ECM. Step Action Value YES NO 1 Perform the OBD system check. Is the procedure completed? — Go to Step 2. Go to “OBD system check”. 2 Is the scan tool (KW communication) available? — Go to Step 3. Go to Step 17. 3 1. Turn the key switch to “ON”. 2. Check for “Main relay voltage” on the data display using scan tool. Is the “Main relay voltage” more than the specified value? 1V Go to Step 4. Go to Step 7. 4 1. Turn the key switch to “OFF”. 2. Check the DTC. Is DTC P1625 detected? — Go to Step 5.
Go to “Diagnostic aid”. 5 1. Remove the main relay. 2. Check the DTC. Note: Refer to the machine’s manual for installing position and installation/removal procedures of the main relay. Is DTC P1625 detected? — Go to Step 6. Go to Step 11.