hitachi — DTC: P1625 (Flash code 416) Main relay fault

Electronic control fuel injection system (Common rail type) 1E-507 Step Action Value YES NO 6 1. Check the circuit (contact point side) between main relay and ECM for short circuit to the power supply circuit or ignition power supply circuit using breaker box or DMM. Refer to “Breaker box inspection procedure”. Note: If breaker box is not available, refer to “On- board check procedure for sensors”. 2. If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 12. Go to Step 15. 7 Check for installation condition of the main relay, ECM connector and coupling connector. 1. Check for play or looseness in the connection. 2.

If the trouble is detected, repair as required. Is the trouble detected? — Go to Step 15. Go to Step 8. 8 1. Turn the key switch to “OFF”. 2. Remove the main relay. 3. Short between the terminals 1 - 2 and 3 - 5 in the main relay installing portion respectively using jump cable. 4. Turn the key switch to “ON”. 5. Check for “Main relay voltage” on the data display using scan tool. Is the “Main relay voltage” more than the specified value? 24V Go to Step 11. Go to Step 9. 9 1. Check for following in the circuit between slow-blow fuse and main relay. • Open circuit • Short circuit to ground circuit • High resistance 2. If the trouble is detected, repair as required. Is the trouble detected?

— Go to Step 15. Go to Step 10.