Electronic control fuel injection system (Common rail type) 1E-51 Step 9 Choose the menu F4: Programming with , (up/ down) keys or F4 (function) key, and press [ENTER]. Step 11 Choose the menu F2: Service mode with , (up/ down) keys or F2 (function) key, and press [ENTER]. F0: Uploads the three-point Q adjust data stored in the ECM to the Tech2. * Registers the data when replacing ECM. F1: Writes the three-point Q adjust data temporarily stored in the Tech2 to the ECM. * Registers to the ECM after replacing ECM. F2: Any data can be written. However, password and ID are required. TSHK0050 Step 10 Choose the menu F0: Q adjust with , (up/ down) keys or F0 (function) key, and press [ENTER].
TSHK0052 Step 12 Password input screen This procedure will end automatically if the registration is not completed within 120 seconds. The message “Time Over” appears. TSHK0051 TSHK0053