hitachi — Installation

1B-14 Engine Mechanical (6WG1 (Common rail)) 2. Install the generator to the bracket and adjustment plate. Legend 1. Push gauge 2. Iron plate 3. Amount of tension Legend 1. Belt 2. Adjustment nut 3. Adjustment bolt (generator) 4. Bolt (generator) 5. Adjustment bolt (Idling pulley) Loosen the generator's installation bolt and lock nut, then loosen the idling pulley lock nut. In order to set the amount of tension to within the standard value range when approximately 98 N {10 kgf} of force is applied to the central section of the belt, correctly adjust the balance using the generator adjustment bolt and idling pulley adjustment bolt.

After adjusting the tension of the belt, tighten the locknuts (1) and (3), and the installation bolt (6). 3. Install the belt (for the generator) and adjust the tension of the belt. Secure the reliable standard position by setting a standard string (1) or a weighted at both ends string (2) on the back of the belt. Idling pulley tightening torque: 147N m {15kgf m} Arrange the push gauge so that the edge of the push gauge presses uniformly on the overall width of the belt, or set an iron plate with a thickness of about 2 mm on the belt.