hitachi — Inspection

1B-112 Engine Mechanical (6WG1 (Common rail)) Soft-nitrating process layer inspection Use a syringe or glass rod to drop the inspection solution onto the inspection section. At this time, make sure that the drop sections are kept level and that the inspection solution does not run or drip off. * Inspection solution…a 5~10% solution of chlorinated-2-copper ammonium dissolved in distilled water. Presence of soft-nitrating process layer Crankshaft cleaning Clean the crankshaft. Especially in inspection points (excluding a 10mm range around the perimeter of the oil pore) remove oil using organic solvents. Legend 1. Do not inspect the range within 10mm of the oil pore 2. Inspection solution 3.

Crankshaft Judgement Crankshaft re-usable: No change is visible after 30~40 seconds has elapsed. Crankshaft is not re-usable: After 30~40 seconds has elapsed, the inspection solution (light blue color) becomes transparent, and the applied section of crankshaft changes to copper color. Process after inspection The inspection solution (1) is highly corrosive, so should be wiped from the inspection surface immediately after inspection and the surface should be cleaned with water or steam. Caution: Do not allow the solution to come into contact with eyes, hands, or clothing.

Should the liquid get into someone's eye, immediately wash with large amounts of fresh water and seek immediate medical attention.