hitachi — Assembly

1E-18 Electric system (6WG1 (Common rail)) After adjusting the pinion's pulled out position, connect the starter as shown in the diagram. Notes: Use an electrical wire that is thick enough, and make sure that connection sections are thoroughly tightened. Legend 1. Battery 2. Ampere meter 3. Voltmeter Close the switch and read-off the number of revolutions, current, and voltage. Compare the read values to the maintenance standard. If the values differ from the maintenance standard values, disassemble and inspect again. 8.

Maintenance standard Heading Standard values and limitation values No load characteristic Voltage (V) 23.5 Current (A) Less than 125 Number of revolutions (r/min) Over 3000 Commutator Outer diameter (mm) 38.7 Reduced dimensions limit (mm) 38.1 Commutator Undercut (mm) 0.8 Limit (mm) 0.2 Brush Length (mm) 23 Reduced dimensions limit (mm) 12 Brush spring Pressure (N) 33 – 45 Limit (N) 20 Pinion's pulled out position (mm) 0.5 – 2.0