hitachi — Service Precautions

1E-20 Electric system (6WG1 (Common rail)) Charging system Service Precautions Always detach the battery terminal (-) before inspecting equipment. Do not open and close the battery relay switch while the engine is rotating. If using a quick charger etc. or recharging from an external source, always detach the battery terminals first. To not use a steam cleaner or apply water directly. After wiring, tighten the B terminal and E terminal to the correct tightening torque shown below. B terminal 4.9 ~ 6.9 N m {0.5 ~ 0.7 kgf m} E terminal 2.0 ~ 5.3 N m {0.2 ~ 0.5 kgf m} For details on adjusting the belt tension, refer to the section on belt adjustment.

The following precautions apply when handling the generator. Connecting to the reverse battery polarities will cause damage to the generator diodes. Do not under any circumstances remove the battery terminals or an electrical wire from the charging circuit while the engine is rotating. Install each of the terminal wires to the correct terminal without mistakes. Do not perform a Megger test on semiconductor devices. Explanation of functions and operations Generator cross section diagram Legend 1. Rectifier 2. Stator 3. Rotor 4. Bearing 5. Pulley 6. Front bracket 7. Coil ASM 8. Rear bracket 9. IC regulator 10. Bearing