Electric system (6WG1 (Common rail)) 1E-21 Charging circuit Legend 1. Coil 2. Diode 3. Condenser 4. Indicator lamp 5. Key switch 6. Battery 7. Connector 8. Regulator 9. Field coil Generator main configuration and functions In order to change the 3 phase Alternating Current generated by the starter coil into Direct Current, the generator uses 6 main diodes and 2 additional diodes. 3 of the 6 main diodes are called plus diodes, and the remaining 3 are called minus diodes. Furthermore, 3 smaller diodes called trio diodes are used, and these diodes provide the field current. The generator has 3 terminals, B terminal (direct current output terminal), L terminal and R terminal.

The L terminal is connected to the field coil. Until the generator starts to generate power, the L and R terminals are used for the input of initial excitation current. They also function as output terminals. (1 ampere current capacity) When the L terminal voltage reaches the battery voltage, the charging lamp goes out. This is a brush less generator. The generator mainly consists of a rotor, starter, rectifier ASM, front bracket, rear bracket, IC regulator, bearing, and pulley etc.