Electric system (6WG1 (Common rail)) 1E-33 Functional check: Generator bench test Output voltage test The output voltage test inspects whether the generator can give out the rated output or not. After the adjustment voltage inspection, reduce the generator's rotation speed and stop the generator. Close switch 1. The lamp lights. Increase the load resistance value to the maximum value (minimum voltage) and close switch 2. Increase the generator's rotation speed, and while keeping the speed at 5000 rpm, adjust the load resistance so that the output voltage is at a maximum. Keep the generator rotating in this condition for 15 minutes to raise the temperature of the generator.
After 15 minutes, alter the generator's rotating speed to the rotating speed shown in the adjustment standard (2500 and 5000 rpm). In this condition, adjust the load resistance so that the output voltage is at a maximum. At this time, if the voltmeter's display shows a value that is within the maintenance standard values, the generator is operating correctly. If the value is below the maintenance standard values, refer to the section on generator [Inspection] and re-inspect the generator. Adjustment voltage inspection Wire as shown in the diagram. Use a 100 A rated ampere meter, and a 30V rated voltmeter.
Use a 50A or over rated ampere meter for testing parts that have adjustable load resistance. Close switch 1. Leave switch 2 open. At this time the lamp will light. If the lamp does not light, inspect the L terminal's voltage. If the voltage is close to the battery's voltage, inspect the generator. If the voltage is low, there is a broken wire in the lamp or lamp circuit. Gradually increase the generator's rotation speed. Check that the lamp remains out until the rotation speed is approx. 1300 rpm. Observe the voltage. If the voltage exceeds 30 V without being controlled, a fault in the IC regulator must be considered.
If the voltage does not increase over the battery voltage, the generator is not generating electricity. Re-inspect the generator. If the lamp does not go out, re-inspect the generator. Increase the generator's rotation speed to approx. 5000rpm and read the ampere meter reading. If the reading is below 5 A, read the voltmeter reading. This is the adjustment voltage. If the ampere meter reading is above 5 A, continue to recharge until the reading drops below 5 A, or replace the battery with a fully recharged battery. If the adjustment voltage falls outside the reference value, replace the regulator.
Maintenance standard Rotating speed 2500 rpm 5000 rpm Output characteristics (when hot) Voltage 27 V 27 V Current More than 42 A More than 50A Field coil resistance (at 20°C) 4.4 ~ 5.2 Ω Regulator adjustment voltage 28 ~ 29 V Rotation direction (viewed from the pulley side) Clockwise direction