hitachi — Method to identify using non-contact infrared thermometer

Electronic control fuel injection system (Common rail type) 1E-83 Changes in the temperature in the normal condition Changes in the temperature when injection in one of No. 2 to No. 5 cylinders stops 500 (932) 500 (932) 400 (752) 400 (752) C ( F) 300 (572) C ( F) #2 - #5 300 (572) #6 200 (392) 100 (212) 200 (392) 0 (32) TSHK0135 TSHK0137 In the normal condition, the temperature of the No. 6 cylinder keeps lower than others. When injection in one of No. 2 to No. 5 cylinders stops, the temperature of the stopped cylinder keeps lower than normal cylinders. Changes in the temperature when injection in 1st or No.

6 cylinder stops Refer to the relevant section for the reference value of Hitachi Construction Machinery. 500 (932) 400 (752) 300 (572) C ( F) 200 (392) 100 (212) #1/#6 0 (32) When injection in No. 1 or No. 6 cylinder stops, there are significant difference in the temperature between No. 1 or No. 6 cylinder and other cylinders that perform normal injection. TSHK0136