MAN — Removing and installing injection pump

Removing and installing injection pump Fig. 5 Remove the mounting bolts from the injection pump flange. The screw plug for the inspection hole in the mounting flange of the injection pump (arrow) is removed. Note: For reasons of space the mounting bolt between the injection pump and the crank- case (hexagon M10 bolt with reduced head 13 mm) can be reached only with a 3/8” socket and an extension. 5 4299 Take off injection pump. Note: Ensure meticulous cleanliness when work- ing on the injection pump. Prevent dirt and foreign matter from pene- trating into opened line connections. Installing injection pump Fig. 6 6 4286 Check whether engine is at start of delivery.

The start of delivery of individual engines is indi- cated in the publication ”Engineering S Data S Set- ting values”. Fig. 7 Check whether the injection pump is in delivery start position. To do this, remove the screw plug from injection pump flange (see Fig. 5). The deliv- ery start pointer must be visible in the centre of the inspection hole. Fig. 8 6 2329 Remove the mounting bolts from the injection pump drive gear so that it can be turned in the slots. Hold injection pump camshaft in place while turn- ing the gear. Fit new O-ring (slightly coated with oil) to injection pump flange. 8 3400 29