Kaiyi — Kaiyi Hydraulic Systems Maintenance Manual

6-47 Problem Cause Remedy No steering or hydraulic function Low oil level. Failed hydraulic pump. Add recommended oil. Remove and inspect return filter for metal pump particles. No hydraulic functions steering normal Failed hydraulic pump. Failed line filter. Faulty safety valve. Stuck open port relief valve. Remove and inspect return filter for metal pump particles, or replace the pump. Remove and inspect line filter for RCV. Safety valve leakage test or ON, OFF function test. Replace relief valve. Boom float function does not work Low pilot control pressure. Faulty pilot control valve (RCV). Loader control valve (MCV) spool binding in bore.

Do pressure reducing valve pressure test in group 3. Replace relief valve. Do pressure reducing valve pressure test in group 3. One hydraulic function does not work. Faulty pilot control valve (RCV). Stuck open port relief valve. Oil leaking past cylinder packings. Blockage in oil lines or valve. Loader control valve (MCV) spool stuck in bore. Do pilot control valve pressure test. Inspect and repair valve. Replace relief valve. Do boom and bucket cylinder leakage test in group 3. Inspect lines for damage. Disconnect and inspect lines for internal blockage. Inspect and repair valve. Low hydraulic power Leakage within work circuit. Low system relief valve (main relief valve) setting.

Low port relief valve setting. Leaking system relief valve. Worn hydraulic pump. Faulty pilot control valve (RCV). Do cylinder drift check in group 2. Do loader system and port relief valve pressure test in group 3. Do loader system and port relief valve pressure test in group 3. Remove and inspect valve. Do hydraulic pump performance check in group 2. Do pilot control valve pressure test in group 3.