Kaiyi — Kaiyi Hydraulic Systems Maintenance Manual

10. PILOT CONTROL VALVE (EH CONTROL BLOCK) P PILOT CONTROL VALVE (EH CONTROL BLOCK) P RESSURE TEST RESSURE TEST В SPECIFICATION SPECIFICATION Oil temperature 45 Ь 5 C (113 Ь 9 F) Engine speed High idle Minimum pressure 30 bar Pressure range 35~50 bar EH control block В GAUGE AND TOOL GAUGE AND TOOL Gauge 0~7 MPa (0~70 bar , 0~1000 psi ) P 1) Lower boom to ground. 2) Connect gauge to the pilot pressure port of function to be checked. 3) Install temperature reader (see temperature reader installation procedure in this group). 4) Heat hydraulic oil to specification (see hydraulic oil warm up procedure in this group). Safety valve 760F6WE38 6-61