Perkins — Perkins 854E-E34TA and 854F-E34T Industrial Engines Operation and Maintenance Manual

SEBU8726-03 51 Operation Section Configuration Parameters In most cases, it is not necessary to stop the engine because of an intermittent code. However, the operator should retrieve the logged fault codes and the operator should reference the appropriate information in order to identify the nature of the event. The operator should log any observation that could have caused the lamp to light. Low power Limits of the engine speed Excessive smoke, etc This information can be useful to help troubleshoot the situation. The information can also be used for future reference. For more information on diagnostic codes, refer to the Troubleshooting Guide for this engine.

i05844821 Configuration Parameters The engine electronic control module (ECM) has two types of configuration parameters. The system configuration parameters and the customer specified parameters. The electronic service tool is required in order to alter the configuration parameters. System Configuration Parameters System configuration parameters affect the emissions of the engine or the power of the engine. System configuration parameters are programmed at the factory. Normally, system configuration parameters would never require changing through the life of the engine. System configuration parameters must be reprogrammed if an ECM is replaced.

Customer Specified Parameters Customer specified parameters allow the engine to be configured to the exact needs of the application. The electronic service tool is required in order to alter the customer configuration parameters. Customer parameters may be changed repeatedly as operational requirements change. Table 3 (continued) Customer Specified Parameters Specified Parameters Record Low Idle Speed