SEBU8726-03 73 Maintenance Section Fluid Recommendations Drain the cooling system into a suitable container. Dispose of the coolant according to local regulations. Flush the system with clean water. Fill the system with the Perkins ELC. Table 13 is an example for using the equation that is in Table 12 . Table 13 Drain a portion of the cooling system into a suitable container according to local regulations. Then, fill the cooling system with premixed ELC. This procedure should lower the contamination to less than 10 percent. Maintain the system as a conventional Heavy- Duty Coolant. Treat the system with an SCA.
Change the coolant at the interval that is recommended for the conventional Heavy-Duty Coolant. Adding The SCA to The Heavy-Duty Coolant For Maintenance Heavy-duty antifreeze of all types REQUIRE periodic additions of an SCA. Commercial Heavy-Duty Antifreeze and SCA Test the antifreeze periodically for the concentration of SCA. For the interval, refer to the Operation and Maintenance Manual, “Maintenance Interval Schedule” (Maintenance Section). Cooling System Supplemental Coolant Additive (SCA) Test/Add. NOTICE Commercial Heavy-Duty Coolant which contains Amine as part of the corrosion protection system must not be used. Additions of SCA are based on the results of the test.
The size of the cooling system determines the amount of SCA that is needed. NOTICE Never operate an engine without water temperature regulators in the cooling system. Water temperature regulators help to maintain the engine coolant at the correct operating temperature. Cooling system prob- lems can develop without water temperature regulators. Use the equation that is in Table 14 to determine the amount of SCA that is required, if necessary: Table 14 Equation For Adding The SCA To The Heavy-Duty Coolant For Maintenance Check the antifreeze (glycol concentration) to ensure adequate protection against boiling or freezing.
Perkins recommends the use of a refractometer for checking the glycol concentration. A hydrometer should not be used. V is the total volume of the cooling system. V Ч 0.014 = X X is the amount of SCA that is required. Perkins engine cooling systems should be tested at 500-hour intervals for the concentration of SCA. Table 15 is an example for using the equation that is in Table 14 . Table 15 Additions of SCA are based on the results of the test. An SCA that is liquid may be needed at 500-hour intervals. Adding the SCA to Heavy-Duty Coolant at the Initial Fill Use the equation that is in Table 12 to determine the amount of SCA that is required when the cooling system is initially filled.
Cleaning the System of Heavy-Duty Antifreeze Table 12 Equation For Adding The SCA To The Heavy-Duty Coolant At The Initial Fill Clean the cooling system after used coolant is drained or before the cooling system is filled with new coolant. V Ч 0.045 = X V is the total volume of the cooling system. X is the amount of SCA that is required.
Example Of The Equation For Adding The SCA To The Heavy- Duty Coolant At The Initial Fill Total Volume of the Cooling System (V) Multiplication Factor Amount of SCA that is Required (X) 15 L (4 US gal) × 0.045 0.7 L (24 oz) Example Of The Equation For Adding The SCA To The Heavy- Duty Coolant For Maintenance Total Volume of the Cooling System (V) Multiplication Factor Amount of SCA that is Required (X) 15 L (4 US gal) × 0.014 0.2 L (7 oz)