72 SEBU8726-03 Maintenance Section Fluid Recommendations Containers of several sizes are available. Consult your Perkins distributor for the part numbers. Changing to Perkins ELC ELC Cooling System Maintenance To change from heavy-duty antifreeze to the Perkins ELC, perform the following steps: NOTICE Care must be taken to ensure that all fluids are con- tained during performance of inspection, mainte- nance, testing, adjusting and the repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disas- sembling any component containing fluids.
Correct additions to the Extended Life Coolant NOTICE Use only Perkins products for pre-mixed or concen- trated coolants. Dispose of all fluids according to local regulations and mandates. Mixing Extended Life Coolant with other products re- duces the Extended Life Coolant service life. Failure to follow the recommendations can reduce cooling system components life unless appropriate corrective action is performed. 1. Drain the coolant into a suitable container. 2. Dispose of the coolant according to local regulations. To maintain the correct balance between the antifreeze and the additives, you must maintain the recommended concentration of ELC.
Lowering the proportion of antifreeze lowers the proportion of additive. This will lower the ability of the coolant to protect the system from pitting, from cavitation, from erosion, and from deposits. 3. Fill the cooling system with a 33 percent solution of Perkins ELC and operate the engine, ensure that the thermostat opens. Stop the engine and allow the engine to cool. Drain the coolant. NOTICE Do not use a conventional coolant to top-off a cooling system that is filled with Extended Life Coolant (ELC). Note: Use distilled or deionized water in the solution. 4. Again, fill the cooling system with a 33 percent solution of Perkins ELC and operate the engine ensure that the thermostat opens.
Stop the engine and allow to cool. Do not use standard supplemental coolant additive (SCA). 5. Drain the cooling system. When using Perkins ELC, do not use standard SCA's or SCA filters. NOTICE Incorrect or incomplete flushing of the cooling system can result in damage to copper and other metal components. ELC Cooling System Cleaning Note: If the cooling system is already using ELC, cleaning agents arenot requiredto be used at the specified coolant change interval. Cleaning agents are only required if the system has been contaminated by the addition of some other type of coolant or by cooling system damage. 6. Fill the cooling system with the Perkins Premixed ELC. Operate the engine.
Ensure that all coolant valves open then stop the engine. When cool check the coolant level. ELC Cooling System Contamination Clean water is the only cleaning agent that is required when ELC is drained from the cooling system. NOTICE Mixing ELC with other products reduces the effective- ness of the ELC and shortens the ELC service life. Use only Perkins Products for premixed or concen- trate coolants. Failure to follow these recommenda- tions can result in shortened cooling system component life. Before the cooling system is filled, the heater control (if equipped) must be set to the HOT position. Refer to the OEM to set the heater control.
After the cooling system is drained and the cooling system is refilled, operate the engine until the coolant level reaches the normal operating temperature and until the coolant level stabilizes. As needed, add the coolant mixture to fill the system to the specified level. ELC cooling systems can withstand contamination to a maximum of 10 percent of conventional heavy-duty antifreeze or SCA. If the contamination exceeds 10 percent of the total system capacity, perform ONE of the following procedures: