Perkins — Perkins 854E-E34TA and 854F-E34T Industrial Engines Operation and Maintenance Manual

SEBU8726-03 71 Maintenance Section Fluid Recommendations Most conventional antifreezes use ethylene glycol. Propylene glycol may also be used. In a 1:1 mixture with water, ethylene and propylene glycol provide similar protection against freezing and boiling. Refer to Table 9 and refer to table 10 . Table 9 Perkins recommends a 1:1 mixture of water and glycol. This mixture of water and glycol will provide optimum heavy-duty performance as an antifreeze. This ratio may be increased to 1:2 water to glycol if extra freezing protection is required. A mixture of SCA inhibitor and water is acceptable but will not give the same level of corrosion, boiling and, freezing protection as ELC.

Perkins recommends a 6 percent to 8 percent concentration of SCA in those cooling systems. Distilled water or deionized water is preferred. Water which has the recommended properties may be used. NOTICE Do not use propylene glycol in concentrations that exceed 50 percent glycol because of the reduced heat transfer capability of propylene glycol. Use ethyl- ene glycol in conditions that require additional protec- tion against boiling or freezing. Table 11 Table 10 (1) Use the interval that occurs first. The cooling system must also be flushed out at this time. To check the concentration of glycol in the coolant, measure the specific gravity of the coolant.

ELC Coolant Recommendations Perkins provides ELC for use in the following applications: Heavy-duty spark ignited gas engines ELC Extended Life Coolant Heavy-duty diesel engines SCA Supplement Coolant Additive Automotive applications ASTM American Society for Testing and Materials The anti-corrosion package for ELC is different from the anti-corrosion package for other coolants. ELC is an ethylene glycol base coolant. However, ELC contains organic corrosion inhibitors and antifoam agents with low amounts of nitrite. Perkins ELC has been formulated with the correct amount of these additives to provide superior corrosion protection for all metals in engine cooling systems.

The following two coolants are used in Perkins diesel engines: Preferred – Perkins ELC Acceptable – A commercial heavy-duty antifreeze that meets “ASTM D6210” specifications ELC is available in a premixed cooling solution with distilled water. ELC is a 1:1 mixture. The Premixed ELC provides freeze protection to −36 °C (−33 °F). The Premixed ELC is recommended for the initial fill of the cooling system. The Premixed ELC is also recommended for topping off the cooling system. NOTICE The 854 industrial engines must be operated with a 1:1 mixture of water and glycol. This concentra- tion allows the NOx reduction system to operate correctly at high ambient temperatures.

NOTICE Do not use a commercial coolant/antifreeze that only meets the ASTM D3306 specification. This type of coolant/antifreeze is made for light automotive applications. Ethylene Glycol Concentration Freeze Protection 50 Percent −36 °C (−33 °F) 60 Percent −51 °C (−60 °F) Coolant Service Life Coolant Type Service Life (1) Perkins ELC 6,000 Service Hours or Three Years Commercial Heavy-Duty Anti- freeze that meets “ASTM D6210” 3000 Service Hours or Two Year Commercial SCA inhibitor and Water 3000 Service Hours or One Year Propylene Glycol Concentration Freeze Protection 50 Percent −29 °C (−20 °F)