Komatsu — CHECK BEFORE STARTING ENGINE, ADJUST

. OPERATION OPERATION CHECK ELECTRIC WIRING WARNING CHECK BRAKE PEDAL TRAVEL WARNING 3 - 97 If fuses are frequently blown or if there is a short circuit in the electri cal wiring, locate t he c ause and repair or c ontac t your Komatsu distributor. Accumulation of flamm able material (dead leaves, twigs, gr ass, etc.) a round the battery may cause fire , so alway s chec k and remove such material. Keep the top surface of the battery clean and chec k the bre ather hole i n the b attery cap. I f it is clogged with dirt o r dust, wash the battery cap to clear Check for damage and wrong capacity of the fus e and an y sign of disconnection or sho rt circuit i n the electric w iring.

Check also for loose te rminals and tighten any loose pa Check the wiring of the "battery", "starting moto r" and " alternator" carefully in particul Always check if there is any accumulation of fla mmable material aroun d the battery, and r emove such flammable material. Contact your Komatsu distributor for investigati on and c orrection of the cause. If t he brake pedal stroke is not 60 to 80 mm (2.4 to 3.1 in) (below 60 mm or over 8 0 mm), the b rake and s teering force i s too s trong or insufficient. If the strok e is 81 mm (3.1 in) or longe r, adjust i t. 1. Depress the brake pedal all the way until it stops. 2.

Check that the dista nce of travel (A) at the c enter of the peda is 60 to 80 mm (2.4 to 3.1 in). 3. When this value ex ceeds 81 mm (3.1 in), o r the bra ke fails to work, please conta ct your Komatsu distribu tor for a djustment