MAINTENANCE MAINTENANCE PROCEDURE 5. Remove cover (1) on the top of hydraulic tank, then remove the cap of oil filler port (F). 6. Set the oil container under the drain plug under the machine. Using the handle, remove drain plug (P) and drain the oil. Check the O-ring installed to plug (P), and if it is damaged, replace the O-ring. After draining the oil, tighten drain plug (P). Tightening torque: 68.6 ± 9.81 N•m (7 ± 1 kgf•m, 50.6 ± 7.2 lbft) When removing drain plug (P), be careful not to get oil on yourself. 7. Loosen 4 bolts and remove cover (2). When doing this, the cover may fly off under the force of spring (3), so hold the cover down while removing the bolts. 8.
Pull the top of rod (4) up from the top, and remove spring (3) and strainer (5). 9. Remove any dirt stuck to strainer (5), then wash in clean diesel oil or flushing oil. If strainer (5) is damaged, replace it with a new part. 10. When installing, insert strainer (5) into protrusion (6) of the tank to assemble it. 11. Install cover (2) with the bolts. Check the O-ring fitted to cover (2), and if it is scratched or damaged, replace it with a new O-ring. 12. Add oil engine through oil filler port (F) to the specified level. Check that the oil is between the H and L marks on the sight gauge.
For details of the method of checking oil level, see "CHECK OIL LEVEL IN HYDRAULIC TANK, ADD OIL (PAGE 3-43)". 13. Extend the boom, arm, and bucket cylinder fully as shown in the diagram on the right, remove the oil filler cap, then install the cap and pressurize the inside of the tank. NOTICE Be sure to pressurize the hydraulic tank. If it is not pres- surized, the pump will suck in air, and this will adversely affect the equipment. 14. After replacing hydraulic oil and cleaning or replacing fil- ter element and strainer, bleed air from the circuit. For details of the method of bleeding the air, see "BLEEDING AIR FROM HYDRAULIC SYSTEM (PAGE 4-50)". 4-75