Cooling System/Remove Coolant Heater INSTALL WATER MANIFOLD 1. Install a new O-ring into water manifold and water pump fitting bores. Lubricate O-rings with grease to ease bypass pipe installation. Install bypass pipe (A) into bore of water manifold (B), be careful not to cut O-ring. RG5855 -UN-13AUG91 2. Using LOCTITE 518 Flexible Sealant and a new gasket, install water manifold assembly. Be sure water manifold is properly positioned on spring pin (in front face of cylinder head) and that bypass pipe is fully seated in water manifold and water pump fitting bores. 3.

Apply LOCTITE 242 Thread Sealer to water manifold-to-cylinder head cap screw threads 360 degrees (except for the leading one to three threads). Tighten water manifold cap screws to 61 N·m (45 lb-ft)—Cast Iron housing, 20 N·m (15 lb-ft)—Aluminum housing.. 4. Install bypass pipe “J” clamp to inside-upper injection pump gear cover cap screw and tighten to 27 N·m (20 lb-ft). 5. If equipped, install aftercooler hose to water manifold, and bleed line from cylinder head-to-thermostat housing. RG,CTM42,G25,28-19-14FEB95 REMOVE COOLANT HEATER—IF EQUIPPED 25 24 1. Unplug heater (A) from electrical power source. 2. Drain cooling system. RG5948 -UN-30AUG91 3.

Remove electrical cord, loosen nut, and pull heater element out of block. RG,CTM42,G25,29-19-29OCT92 CTM42 (24MAR95) 25-24 6076 Diesel Engines—S.N. (500000— ) 160101 PN=243