Cooling System/Remove Water Manifold INSTALL THERMOSTATS 1. Apply LOCTITE 518 Flexible Sealant to water manifold-to-thermostat cover mating surface. NOTE: Install thermostats in slot in housing first, then install gasket after thermostat is properly seated in housing. RG5280 -UN-09DEC88 2. Install thermostats (A) and a new gasket (B). 3. Install cover and tighten cap screws to 47 N·m (35 lb-ft)—Cast Iron housing, 20 N·m (15 lb-ft)—Aluminum housing. IMPORTANT: Air must be expelled from cooling system when system is refilled.
Loosen temperature sending unit fitting at rear of cylinder head, bleed plug or petcock at top front of cylinder head, or plug in thermostat housing to allow air to escape when filling system. Retighten fitting or plug when all the air has been expelled. RG,CTM42,G25,25-19-14FEB95 REMOVE WATER MANIFOLD 1. Remove air bleed line from cylinder head-to-thermostat housing (if equipped) and aftercooler hose from water manifold-to-aftercooler (if equipped). 25 23 RG5854 -UN-13AUG91 2. Remove three water manifold-to-cylinder head cap screws (A) and remove water manifold assembly. NOTE:
Pull water manifold straight ahead (toward front of engine) approximately 6.35 mm (0.25 in.) to disengage from locator (spring) pin (B), then lift straight up to disengage from bypass pipe (C). 3. Remove bypass pipe. Remove and discard O-rings from bore of water manifold and from water pump fitting. CTM42 (24MAR95) 25-23 6076 Diesel Engines—S.N. (500000— ) RG,CTM42,G25,26-19-29OCT92 160101 PN=242