Fuel System/Service Injection Pump Overflow Valve DISASSEMBLE AND CLEAN HYDRAULIC ANEROID ACTIVATOR PARTS—IF EQUIPPED 1. Remove gasket (G), piston (F) and piston spring (E). 2. Wash all parts in clean solvent and dry with compressed air. Blow out all openings to make sure they are open. RG3547 -UN-20DEC88 3. Check piston (F) and activator housing (H) for general condition. Piston must move freely in its bore. 4. Inspect piston spring (E) and capillary valve spring (L). Replace if weak or broken. 5. Inspect condition of restricter wire (K). Wire must not A—Starting Fuel Control I—Mounting Screw (2 be bent or broken and must fit loosely in capillary valve Shaft used) (J).
B—Return Spring J—Capillary Valve C—Washer K—Restricter Wire D—Retaining Ring L—Capillary Valve 6. Check condition of return spring (B), washer (C) and E—Piston Spring Spring retaining ring (D) on starting fuel control shaft (A). F—Piston M—Washers Replace spring if weak or broken. Be sure retaining ring G—Gasket N—Special Screw is secure on shaft. H—Activator Housing RG,CTM42,G35,71-19-14FEB95 ASSEMBLE AND INSTALL HYDRAULIC ANEROID ACTIVATOR—IF EQUIPPED NOTE: Refer to previous illustration. 1. To assemble and install activator, reverse disassembly procedure using new gaskets. RG,CTM42,G35,83-19-14FEB95 SERVICE INJECTION PUMP OVERFLOW VALVE 35 22 NOTE:
Overflow valve can be serviced with injection pump installed. RG5872 -UN-19AUG91 1. Remove leak-off line (A) and remove elbow (B). 2. Remove valve assembly (C) from pump. CTM42 (24MAR95) 35-22 6076 Diesel Engines—S.N. (500000— ) RG,CTM42,G35,16-19-28OCT92 160101 PN=299