John Deere 400 6076 — John Deere 400 6076 User Manual

Fuel System/Perform Opening Pressure Test PERFORM OPENING PRESSURE TEST 1. Connect injection nozzle to D01109AA Nozzle Tester (Y900) (A), using No. Y900-2A Fuel Line (B) and Y900-7 and Y900-15 Straight Adapters (C). Y900-21 90˚ Adapter may also be used. Place a glass beaker (D) around nozzle. 2. Pump handle several times to flush out nozzle fittings. Tighten fittings. 3. Expel air from nozzle by operating pump handle several strokes. Then raise pressure until valve opens. RG5883 -UN-19AUG91 4. Recheck by completely releasing pressure, then gradually building pressure until valve opens. IMPORTANT: Nozzle tester should be checked periodically for accuracy.

A—Nozzle Tester B—Fuel Line C—Adapter D—Beaker RG,CTM42,G35,30-19-03OCT92 35 43 CTM42 (24MAR95) 35-43 6076 Diesel Engines—S.N. (500000— ) 160101 PN=320