John Deere 400 6076 — John Deere 400 6076 User Manual

Engine Tune-Up and Break-In/Check Air Intake System CHECK CRANKCASE VENTILATION SYSTEM 1. Inspect crankcase ventilation system for restrictions. Lack of ventilation causes sludge to form in engine crankcase. This can lead to clogging of oil passages, filters, and screens; resulting in serious engine damage. 2. Clean crankcase vent tube (A) with solvent and compressed air if restricted. Install and tighten hose clamps securely. RG5930 -UN-20AUG91 RG,CTM42,G100,1-19-29OCT92 CHECK AIR INTAKE SYSTEM 1. Replace air cleaner primary filter element. Replace secondary element if primary element has holes in it. 2. Check condition of air intake hose(s).

Replace hoses that are cracked, split, or otherwise in poor condition. RG4689 -UN-20DEC88 3. Check hose clamps (A) for tightness. Replace clamps that cannot be properly tightened. This will help prevent dust from entering the air intake system which could cause serious engine damage. S11,22010,CU -19-08APR94 100 7 CTM42 (24MAR95) 100-7 6076 Diesel Engines—S.N. (500000— ) 160101 PN=346