Fuel System Operation and Test/Bleed the Fuel System 2. Unscrew hand primer on fuel supply pump until it can be pulled by hand (Nippondenso pumps only). NOTE: Robert Bosch supply pumps use a hand primer that is spring loaded and remains fully extended during normal engine operation. RG5903 -UN-19AUG91 115 30 3. Operate the hand primer (A) on fuel supply pump until a smooth flow of fuel, free of bubbles, comes out of the filter plug hole. IMPORTANT: On Nippondenso pumps, be sure hand Bosch Pump Shown primer is all the way down in barrel before tightening to prevent internal thread damage. 4. Simultaneously stroke the hand primer down and close the filter port plug.
This prevents air from entering the system. Tighten plug securely. DO NOT overtighten. 5. Lock hand primer in position (Nippondenso pumps only). NOTE: If the engine will not start, it may be necessary to loosen the fuel pipes at the injection nozzles to bleed air from system. Put the hand throttle in slow idle position. Push the engine fuel shut-off control knob all the way in. Turn the engine with the starter until fuel without air flows from the loose fuel pipe connections. Tighten the connections. RG,CTM42,115,9 -19-28OCT92 B. At Round Fuel Filter: NOTE: This procedure is for engine applications with electric fuel supply pumps. 1. Open air bleed vent screw two full turns by hand.
RG6482 -UN-26OCT92 2. Turn key switch “ON” until a noticeable amount of fuel and air comes out of vent opening. Close vent screw when fuel starts to flow. CTM42 (24MAR95) 115-30 6076 Diesel Engines—S.N. (500000— ) RG,CTM42,G35,93-19-02NOV92 160101 PN=413