John Deere 400 6076 — John Deere 400 6076 User Manual

Fuel System Operation and Test/Check Fast Idle Speed—In-Line Fuel Injection Pump CHECK FAST IDLE SPEED—IN-LINE FUEL INJECTION PUMP 1. Remove speed control rod. With the engine running, move governor control lever (A) against the fast idle stop screw (B). RG3600 -UN-14DEC88 115 34 NOTE: The governor control lever on injection pump may be inboard (next to engine block) or outboard (away from engine block), depending upon engine application. 2. Using a tachometer, check fast idle speed to see if it is within specification. NOTE: For each application, refer to the appropriate machine technical manual for fast idle speed specifications.

If fast idle speed must be adjusted, see your authorized diesel repair station. NOTE: For some applications such as generator sets, special equipment may be required for fast idle adjustment in conjunction with droop adjustment. See your OEM dealer or John Deere Engine Distributor. RG,CTM42,115,14-19-28OCT92 CTM42 (24MAR95) 115-34 6076 Diesel Engines—S.N. (500000— ) 160101 PN=417