24. SERVICE PROCEDURE 1. Stop the engine and close corrosion resistor valve 0. 2. Turn radiator cap 0 slowly until it comes off. 3. Set a container to catch the coolant, open drain valve 0 at the bottom of the radiator and drain plugs 0 at the both sides of cylinder block, and drain off the cooling water. After draining, close up drain valve 0 and plugs 0 and pour in clean water (ex. city water) up to the vicinity of the water filler. When the water reaches the vicinity of the water filler, put the engine at low idling, open drain valve 0 and plugs 0, then pass water through the cooling system for 10 minutes. When doing this, keep the radiator filled up to the filler with water.
When filling with water, be careful to check that the hose supplying the water does not come out of the water filler port at the radiator cap. 4. 5. 6. After washing the cooling system, stop the engine. Drain water and close drain valve 0 and plugs @. After draining off the cooling water, wash out the cooling system using commercially available detergent. Follow the instructions on the detergent container. After flushing, open drain valve 0 and drain plugs @, completely drain all the water, then close the drain valve and drain plug, and fill with city water up to near the filler port.
When the tank is filled to near the water filler port, open drain valve 0 and drain plugs Q, start the engine, run at low idling, and continue the flushing operation until clean water comes out. Adjust the amount of water flowing in and out to ensure that the radiator is always full during the flushing oper- ation. 7. 8. 9. 3-25