24. SERVICE PROCEDURE 9. When clean water comes out, stop the engine, and close drain valve 0 and drain plugs 0. 11. Replace the corrosion resistor cartridge and open valve 0. For details of replacement of the corrosion resistor, see “24.5 EVERY 500 HOURS SERVICE”. 12. Suply water until it overflows from water filler. 13. Run the engine for 5 minutes at low idling and then for another 5 minutes at high idling to eliminate air trapped in the cooling system (leave radiator cap 0 off during this operation). 14. Stop the engine and wait for about 3 minutes. Supply cooling water up to the water filler. Tighten radiator cap 0. 3-26