24. SERVICE PROCEDURE 24.2.2 CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT l Never clean or replace the air cleaner element with l When using pressure air to clean the element wear safety glasses or goggles to protect the eyes. Checking Whenever the red piston clean the air cleaner element. in dust indicator 0 Loosen wing nut 0, and remove outer element 0. Cleaning or replacing outer element 1. 2. Clean the air cleaner body interior. 3. Direct dry compressd air (less than 700 kPa (7 kg/cm*, 100 psi)) to the element from inside along its folds, then direct it from outside along its folds and again from inside. Remove one seal from the outer element.
The number 1) L of times the outer element has been cleaned can be seen by the number of removed seals. Replace the outer element which has been cleaned 6 times repeatedly or used throughout a year. Replace the inner element at the same time. Replace both inner and outer elements when the dust indicator red piston appears soon after installing the cleaned outer element even though it has not been cleaned 6 times. Check inner element mounting nuts for looseness and, if necessary, retig hten. Replace seal washer 0 or wing nut 0 with new parts if they are broken. 2) 3) 4) 5) 3-27