MAINTENANCE Water Use water which has a low mineral content. Water used in conjunction with antifreeze, coolant filters and inhibited water must meet the following standards: Dissolved Solids - Not to exceed 340 parts per million (20 grains/gallon maximum) to minimize sludge deposits, scale deposits, corrosion or a combination of these. Total Hardness - Not to exceed 170 parts per million (10 grains/gallon maximum) to prevent scale deposits. Water containing dissolved magnesium and calcium (the usual reason for water hardness) above the specified amount will cause scale deposits to develop in the engine.
If any of the above requirements cannot be met, use distilled, de-ionized, or de-mineralized water. To determine if local water supplies meet these standards, water samples can be tested by water treatment laboratories. “Softened” water that is prepared using common salt (sodium chloride) contains excessive amounts of chlorides and should not be used. Chlorides - Not to exceed 40 parts per million (2.5 grains/gallon maximum) to prevent corrosion. Sulfites - Not to exceed 100 parts per million (5.8 grains/gallon maximum) to prevent corrosion. NOTE: Never use water alone in the cooling system because corrosion will occur.
Antifreeze In climates where the temperature is above -37°C (-34°F) use a coolant mixture that contains 50 percent antifreeze. Antifreeze is essential in any climate. It broadens the operating temperature range by lowering the coolant freezing point and by raising its boiling point. Do not use more than 50 percent antifreeze in the mixture unless additional freeze protection is required. Never use more than 68 percent antifreeze under any condition. or alcohol as an antifreeze because of its low boiling point. Antifreeze may retain its freeze protection for more than one season but coolant conditioners must be added to maintain corrosion protection.
Antifreeze formulated with methoxy propanol, or propylene glycol, is not recommended for this system. An antifreeze concentration greater than 68% will adversely affect freeze protection and heat transfer rates. Antifreeze concentrations between 68% and 100% actually have a higher freezing point than a 68% antifreeze concentration and should not be used due to reduced heat transfer rates. NOTE: Do not mix types of antifreeze solutions. Mixed solutions make it impossible to determine the protection against freezing. Antifreeze containing sealer or anti-leak additives should NOT be used in this system. Sealer or anti-leak additives will cause plugging problems in the cooling system.
Low silicate ethylene glycol antifreeze is recommended. The antifreeze should contain no more than 0.1% anhydrous alkali metasilicate. Low silicate antifreeze is recommended to avoid the formation of silica-gel (hydro-gel). This gel formation can occur when the cooling system contains an over concentration of high silicate antifreeze and/or supplemental coolant additive. DO NOT use methanol Check the solution periodically and at normal operating temperature, to be sure the cooling system has sufficient protection against freezing. The following table shows the approximate percentage of antifreeze solution required for various temperatures. 3-13