Komatsu — COOLANT

MAINTENANCE NOTE 3 - Change the coolant filter at every engine oil and filter change interval to protect the cooling system. concentrated coolant solution. More than 2.0 units per 3.8 P (1 US gal) indicates an over-concentrated coolant solution. Maintain a nominal concentration of 1 .O DCA4 unit per 3.8 P (1 US gal) of coolant in the system. Less than 0.5 unit per 3.8 P (1 US gal) indicates an under- To check the DCA4 concentration level, use the Fleetguard coolant test kit, CC2626. Instructions are included with the test kii.

DCA4 Unit Concentration Guide Number of Solution A Drops to Cause Color Change Coolant Condition Action Required 0 - 10 Drops Extremely under-concentrated - Initially charge the system to a less than 0.4 DCA4 units per 3.8 P minimum of 1 .O DCA4 unit per 3.8 (1 US aal) 4 (1 US aal). Marginally under-concentrated - 0.45 to 0.8 DCA4 units per 3.8 0 (1 US gal) Add DCA4 liquid units to maintain 1 .O DCA4 unit per 3.8 P (1 US gal) minimum or change the DCA 4 coolant filter. 11 - 16 Drops 17 - 25 Drops Acceptable - 0.85 to 1.3 DCA4 units per 3.8 P (1 US gal) None. 26 - 35 Drops Highly acceptable - 1.35 to 2.0 DCA4 units per 3.8 Q (1 US gal) None.

36 - 55 Drops Marginally over-concentrated - 2.1 to 3.3 DCA4 units per 3.8 0 (1 US Review maintenance practice. Over 55 Drops Extremely over-concentrated Drain 50% of the coolant and replace with water antifreeze mixture. Retest the svstem for correct DCA4 unit concentration. 3-17