Heating and Air Conditioning 193 Heater Shut-Downs If the heater does not start within two 60 second start attempts, a "no start" shut-down occurs. If a flameout occurs after the heater has started, the heater will attempt to restart. If repeated flameouts oc- cur within 10 minutes, the heater will not restart. Overheat shut-down will occur if there is a restriction of the heating air flow (that is: blocked inlet or outlet). The automatic overheat switch will reset once the heater has cooled down. The blower motor is checked on start-up and every 4 minutes. Shut- down will occur if the blower does not start or maintain proper speed.

If any of these events should occur, the unit should be checked out by a qualified heater technician or contact the manufacturer.