194 Heating and Air Conditioning A/C Diagnostic Module Problem Codes The diagnostic module has two LED lights (one green and one red) which indicate if a system problem has been detected. If a problem is detected, a fault code or “blink” code is activated to identify the condition. The blink codes listed on the label are: Slow Green Normal Fast Green Low system voltage 1 Red Blink Loss of refrigerant W3002004 2 Red Blinks Overcharge, blockage or fan failure 3 Red Blinks Open or shorted clutch or circuit 4 Red Blinks Open pressure switch or circuit The air conditioning system is under pressure. The possibility of an explosion is possible if serviced incorrectly.
A qualified technician should perform any service needed. Failure to follow this may lead to an explosion causing severe injury or death.