SP001727 Page 41 Electrical System Digital Outputs Descriptions Digital Outputs Items Mark Remark 1. Relief Press. Up S/V ON / OFF Lights up when the relief press up solenoid valve is "ON." 2. High Speed S/V Lights up when the high speed solenoid valve is "ON." 3. Reverse Fan S/V N.A. 4. Starter Relay When the starter relay is "ON." 5. After Heat Relay N.A. Menu Select DIGITAL OUTPUT STATE 1. Relief Press. Up S/V : 2. High Speed S/V : 3. Reverse Fan S/V : N.A 4. Starter Relay : 5. Afterheat Relay : N.A : UP : DOWN Page:1/1 FG014293 Figure 30 Failure Information SPECIAL MENU 1. Entering Sub-menus: When a cursor is located in "Failure Info" of special menu screen press enter button ( , 3 on 1.
Machine Info Figure 23) and "Failure Info" screen is displayed. 2. Failure Info 2. Exiting Sub-menus: If escape button (ESC, 4 on Figure 23) is pressed for more than 1 second, this information screen will be returned to previous screen. 3. Operating Hrs : UP : DOWN : SELECT FG000563 Figure 31 * Real-time Failure: Current status of failure is displayed. FAILURE INFO * Failure Log: 1. Realtime Fail Memorized record of past failure is displayed. * Delete Fail Log: 2. Failure Log This mode is used to delete all of the memorized record of past failure. 3. Delete Fail Log : UP : DOWN : SELECT FG000564 Figure 32