Kaiyi DX225LCA — Kaiyi DX225LCA — спецификация (EN)

Operation 1. Power Mode This mode should be selected for high speed work. In this mode the engine output is most efficiently utilized due to the discharged oil volume being controlled based on the equivalent horsepower curve at various loaded pressures. The e-EPOS controller compares the target engine speed with the actual engine speed and controls the signal to the E.P.P.R. (Electromagnetic Proportional Pressure Reducing) valve which in turn varies the pump output quantity. If the load increases, the engine speed will fall below the rated speed.

When this occurs, the controller senses this decrease and immediately reduces the pump discharge volume to maintain the engine speed at the rated level. ARO0260L Figure 51 On the other hand, if the load is decreased the controller increases the discharge volume of the pump to maintain the engine speed at the rated level. By repeating these control operations, the engine speed is maintained at the rated speed so that maximum power can be generated. In Power Mode, the e-EPOS controller receives engine speed signals from the engine control dial and the engine controller (ECU) and converts it to an operating signal current and is then transferred to the pump's E.P.P.R valve.

At this time the E.P.P.R. valve converts the electric signal to the corresponding control pressure and sends it to the two pumps, adjusting the pump discharge volume to the desired level. C A B D FG000580 Figure 52 SP001727 Electrical System Page 54 Reference Number Description A Engine Horsepower (hp) B Engine Speed (rpm) C Pump Discharge Volume (lpm) Reference Number Description D Pump Discharge Pressure (kg/ cm2)