2. Standard Mode Standard Mode is used for general work. When this mode is selected it will reduce noise and fuel consumption in comparison with Power Mode. The current to the E.P.P.R. valve is shut off and pump discharge volume is controlled by pump regulator. C A B D FG000581 Figure 53 3) Operation in case of failure in the control system (Aux mode operation Though it is impossible to control current of the E.P.P.R (Electromagnetic Proportional Pressure Reducing) Valve controlling the discharge volume of pump due to fault in control system, the machine can be operated in the aux mode.
Upon turning "ON" the aux mode switch, the E.P.P.R Valve controlling the discharge volume of pump comes into contact with the aux mode resistor to let current of a certain value flow. At this time, the discharge volume of pump follow the control by the pump regulator, nearly at quantity roughly similar to that in the standard mode. SP001727 Page 55 Electrical System Reference Number Description A Engine Horsepower (hp) B Engine Speed (rpm) C Pump Discharge Volume (lpm) Reference Number Description D Pump Discharge Pressure (kg/ cm2)