Checking and repairing pipe cluster for heat exchanger D Remove pipe cluster, see page 62 Fig. 1 When the pipe cluster is removed, we recommend always checking the position of the deflectors (arrows) (the picture shows the pipe cluster for a D 2848 LE 403 engine). Displaced deflectors may reduce the flow of cool- ant, which in turn leads to an increase in coolant temperature. 1 Fig. 2 Measure the position of the deflectors. Use the pipe-cluster side with the collar (arrow) as refer- ence edge (this side can be recognised as that end of the pipe cluster with the larger diameter). 2 Fig. 3 Reference spacing of the deflectors. A 111 B 207.5 C 304 D 394.5 E 497 F 593,5 G 690 A B C D E F G 3 Fig.
4 If deflectors are found displaced, bring them into their original position. To prevent the deflectors from being displaced again, the 4 outer pipes on the edges (marked black in the picture) are to be soldered on to every deflector. 4 65